Hmmmmm........what to do?? Dump data contains the entire iSCSI header.Event ID 34 iScsiPrt - A connection to the target was lost, but Initiator successfully reconnected to the target. If you are experiencing a similar issue, please ask a related question Suggested Solutions Title # Comments Views Activity how to make a specific windows 2003 GPO setting visible in a The path for logical drive [SN: 60050CC00020188D0000000000000007] has failed over to [0005 4:0:1:2] because of a path error. have a peek here

Unable to successfully cleanup. Even if the service succeeds, the administrator should repair the problem. When I run the 'Configure Cluster Quorum Settings' wizard, pick 'Select the quorum witness', pick ' configure a disk witness' I get the error  No suitable disks exist in Available storage. Creating a new computer account (object) for 'SERVICES' in the domain.

I'd also like to take the opportunity to verify my network configuration for the cluster is correct.Thanks,-Brian

0 0 05/20/14--03:51: Cluster-Aware Updating Contact us about this article Cluster-Aware Updating i yes no add cancel older | 1 | .... | 39 | 40 | (Page 41) | 42 | 43 | .... | 119 | newer HOME | ABOUT US | This initialization can also happen during installation of a component that creates a new log.

Dynamic disk, witch a Microsoft feature is supported, however, on the MSA it could cause problems with the connection to the logical units. Access to the device \Device\Harddisk5\DR5 while is impossible and further an disk erors... Find your self a different (seasoned) HP engineer who actually knows something about physical disk connectivity.Regards, Mike J [MSFT] This posting is provided "AS IS" with no warranties, and confers no You’ll be auto redirected in 1 second.

In Event viewer I see the following: The Wintarget service has detected the creation of a failover cluster. that matches an ID that is maintained ...https://technet.microsoft.com/en-us/library/ee619752(v=ws.10).aspxEvent ID: 16 Source: mpioEvent ID: 16 Source: mpio ... This is bad newsfor me. Claim or contact us about this channel Embed this content in your HTML Search confirm cancel Report adult content: click to rate: Account: (login) More Channels Showcase RSS Channel Showcase 2163011

We appreciate your feedback. Multiple USB devices need t… Storage Software Windows Server 2008 Disaster Recovery Reformatting Your Flash Drive Video by: Faizan This Micro Tutorial will teach you how to reformat your flash drive. Data: 0000: 00 00 04 00 01 00 52 00 ......R. 0008: 00 00 00 00 10 00 08 c0 .......À 0010: 02 00 00 00 0e 00 00 Configuring computer object 'SERVICES in organizational unit OU=Servers,DC=xxxxxx,DC=xxxxx' as cluster name object.

It takes around 2 mins for the second controller to come online after the first has failed. It is all normally worked since 2008 But problems have begun with the beginning of this year. To perform this procedure, you must have membership in Administrators , or you must have been delegated the appropriate authority.To move the Diff Area to a different volume: Caution : When Microsoft Customer Support Microsoft Community Forums United States (English) Sign in Home Windows Server 2012 R2 Windows Server 2008 R2 Library Forums We’re sorry.

I'm eager to finally resolve this issue. http://0pacity.com/event-id/event-id-100-source-w3svc.html You'd be surprised! When we reconnect, it connects no problem but we usually need a reboot to get SQL happy again.Back end storage is an EqualLogic SAN running the 3.4.2 HIT kit. Waiting for notification that Cluster service on node SERVER2 has started.

I would Go to Solution 3 2 3 Participants Netflo(3 comments) LVL 18 Windows Server 20035 Storage3 Storage Software2 SergeyGankin(2 comments) RMFIT LVL 1 6 Comments LVL 18 Overall: Level We saw event ID's 23 and 16 (same as above). I have a vm named Single and I'd like to move its storage from cluster disk 2 to cluster disk 4, but the"Move virtual machine storage" wizard shows only two CSV Check This Out Data: 0000: 00 00 68 00 01 00 c2 00 ..h...Â. 0008: 00 00 00 00 20 00 00 40 .... [email protected] 0010: 00 00 00 00 00 00

Thursday, December 02, 2010 7:30 PM Reply | Quote 0 Sign in to vote We're seeing a similar issue. Use Clear-ClusterNode to manually clean up the nodes. The operations that remain for the Event Log service and all other event providers are not affected when there is a problem with one of the event logs being initialized.

Are you using teaming on your server?

We always recommend to have it as basic disk. Friday, August 27, 2010 7:57 PM Reply | Quote Moderator 0 Sign in to vote Ended up being a problem with the SAN zoning configuration. why should i use Cluster-Aware Updating although i have wsus installed in my enviroment ????? The Target name is given in the dump data.Event ID 27 iScsiPrt - Initiator could not find a match for the initiator task tag in the received PDU.

To fix this problem, open the renamed log file on the system where the file was created. We have a 2 node cluster running Windows 2008 R2 that runs our virtualized appliance, the witness disk resides on another server on the same subnet.  A month ago the servers HP has actually recommended the Microsoft MPIO for our configuration. this contact form Example: Windows cannot unload your registry file EventID.Net Splunk Add-on.

Not quite sure where to go next.

0 0 05/13/14--23:03: c:\clusterstorage Contact us about this article Hello , Environment: Windows server datacenter 2012 R2 i am receives the below error when EventID: 23, Source: mpio. An error occurred creating cluster 'SERVICES'. There are some registry settings that can be configured to increase disk timeout but they don't seem to work when failover clustering is enabled.

In Win Disk Manager this disk shows as offline and reserved.